Name: blood analysis of blood vessels, specifications: 1ml, 3ml, can also be customized according to customer demand, model: ordinary type, safe

Product performance structure and composition:

Blood pressure analysis Blood collection includes a reservoir, a piston, an exhaust device, a needle, a rubber sleeve, a cap and an additive, wherein the accumulator comprises a core rod, a hand and a jacket three parts, the needle comprising a needle hub, a needle holder and a needle tube three section.

Used to collect and save blood samples for in vitro diagnostic tests.

Instructions for use: This product can be used for dynamic, intravenous blood collection, clinician nurses must be through the training of venipuncture techniques, and understand the potential hazards. Must be treated with sterile technology, the skin puncture site, the correct disinfection to keep clean. All patients are subject to comprehensive protection measures.

advantage:

(1) made the first domestic production of blood gas analysis of the professional manufacturers, to fill the domestic history of non-dedicated blood gas collection.

(2) dynamic and intravenous blood can be collected.

(3) strong sealing, the detection accuracy is higher.

(4) automatic additive, to improve the accuracy of the dose, so that the test results more accurate.

(5) reasonable structure and design, so that the product is more practical and operational.

(6) the use of blood gas analysis tube in the dynamic and venipuncture puncture success rate is much greater than the traditional syringe, to avoid the pain caused by multiple puncture patients to reduce complications, shorten the operation time and improve the accuracy of the test results for Patients get better treatment to provide a guarantee.

Steps:

1, remove the blood gas analysis tube from the aseptic pack.

2, remove the needle and put it in a proper position.

3, the core rod forward to the zero scale line and then back to the desired scale.

4, blood gas analysis tube needle down to 45 degrees to 90 degrees angle for puncture.

5, in the dynamic, intravenous pressure to make the sample full of the default scale.

6, the sample collection is completed, immediately put the rubber sleeve on the needle, to avoid air into the blood gas analysis tube to prevent injury to the operator and the patient. And then pull out the needle with the rubber sleeve, discard the sharp material in the collection tube, and press the needle with a cotton swab for at least 5 minutes to prevent bleeding.

7, if the bubble, gently push the core rod from the blood gas analysis tube discharge.

8, cover the cap on the blood gas analysis tube to close the blood gas analysis tube and mark the sample.

9, closed immediately after the mix of samples 5 times, and rub in the palm for 5 seconds to make the sample full anticoagulation.

10, if the sample is stored at room temperature, it must be analyzed within 15 minutes (15 minutes after the analysis of PO2 invalid), if stored in ice water, you must test in 15-30 minutes.

11, before the analysis again mixed blood samples 10 times, and rubbing in the palm for 10 seconds, for hematopoietic and hematocrit detection, re-mixing before the test is very important.

Storage environment:

The sterilized product should be stored in a non-corrosive and well-ventilated room and protected against blood gas analysis tubes.

Precautions:

1, if the needle has been used stabbed, there may be the risk of infection with infectious diseases, should be immediately reported, and follow the hospital regulations to track.

2, to prohibit the back of the jacket jacket, blood collection, should immediately put on the plastic sleeve, so as not to use the needle stabbed.

3, for hemoglobin and hematocrit detection, re-mixing before testing is very important. For the detection of PH, Na, K, iCa, CI, Hb, Hct, GIucose, BUN and Crea, the blood gas analysis tube can be placed at room temperature or ice water for no more than 1 h. For all other test items including PCO2, PO2, lactic acid, the specimen must be tested within 15 minutes. For the detection of lactate, in the specimen collected to the detection process, the blood gas analysis tube should always be stored in ice water.

4, the product in the sterilization period, the packaging is not open and damaged before being sterile, pyrogen-free.

5, please carefully check the product before use, such as packaging damage or moisture, please do not use.

6, the product limited to one-time use, please immediately destroyed after use.

7, always wear gloves throughout the operation to reduce the risk of infection.

8, product contraindications: no.

Safety type: the end of the blood collection needle with a folding safety jacket, safety jacket is located in the needle side, the conventional disinfection and blood collection, the safety jacket up a push, the needle set in the safety jacket groove, Cavity with a needle body locking mechanism, the needle lock, can effectively avoid the use of the needle after the wound and stained with the patient's blood sample tip caused by secondary pollution, easy to use without risk, effectively protect the user's life safety.